Devices » History » Version 7
Aleksander Bešir, 05.01.2011 14:08
| 1 | 1 | Aleksander Bešir | h1. Devices |
|---|---|---|---|
| 2 | |||
| 3 | h2. Input devices (devices that provide measurements' values) |
||
| 4 | |||
| 5 | *Thermometer* |
||
| 6 | Device reports to logic: |
||
| 7 | 2 | Aleksander Bešir | |
| 8 | 1 | Aleksander Bešir | * Current temperature (in °C) |
| 9 | 2 | Aleksander Bešir | |
| 10 | Statistical analysis (user chooses the main time frame and a number of inner sections): |
||
| 11 | |||
| 12 | 1 | Aleksander Bešir | * Maximum temperature (in a series of time frames). |
| 13 | 2 | Aleksander Bešir | |
| 14 | 1 | Aleksander Bešir | > eg.: [2010] = [45°C] (time frame: year 2010, inner sections: 1) |
| 15 | 2 | Aleksander Bešir | |
| 16 | 1 | Aleksander Bešir | > eg.: [January, February, March] = [35°C, 41°C, 39°C] (time frame: from January to March, inner sections: 3) |
| 17 | 2 | Aleksander Bešir | |
| 18 | 1 | Aleksander Bešir | * Minimum temperature (in a series of time frames) |
| 19 | 2 | Aleksander Bešir | |
| 20 | 1 | Aleksander Bešir | > eg.: [from January to March] = [9°C] (time frame: from January to March, inner sections: 1) |
| 21 | 2 | Aleksander Bešir | |
| 22 | 1 | Aleksander Bešir | > eg.: [1.1.2010, 2.1.2010, 3.1.2010] = [10°C, 8°C, 9°C] (time frame: from 1.1.2010 till 3.1.2010, inner sections: 3) |
| 23 | 2 | Aleksander Bešir | |
| 24 | 1 | Aleksander Bešir | * Average temperature (in a series of time frames) |
| 25 | 2 | Aleksander Bešir | |
| 26 | 1 | Aleksander Bešir | > eg.: [Summer 2010] = [39.46°C] (time frame: whole Summer, inner sections: 1) |
| 27 | 2 | Aleksander Bešir | |
| 28 | 1 | Aleksander Bešir | > eg.: [Summer 2010, Fall 2010, Winter 2010] = [39.46°C, 36.10°C, 25.85°C] (time frame: from start of Summer 2010 till end of Winter 2010, inner sections: 3) |
| 29 | 3 | Aleksander Bešir | |
| 30 | *Barometer* |
||
| 31 | Device reports to logic: |
||
| 32 | |||
| 33 | 4 | Aleksander Bešir | * Current air pressure |
| 34 | 3 | Aleksander Bešir | |
| 35 | Statistical analysis (user chooses the main time frame and a number of inner sections): |
||
| 36 | |||
| 37 | * Maximum air pressure (in a series of time frames). |
||
| 38 | |||
| 39 | * Minimum air pressure (in a series of time frames) |
||
| 40 | |||
| 41 | 1 | Aleksander Bešir | * Average air pressure (in a series of time frames) |
| 42 | 4 | Aleksander Bešir | |
| 43 | *Hygrometer* |
||
| 44 | Device reports to logic: |
||
| 45 | |||
| 46 | * Current air humidity |
||
| 47 | |||
| 48 | Statistical analysis (user chooses the main time frame and a number of inner sections): |
||
| 49 | |||
| 50 | * Maximum air humidity (in a series of time frames). |
||
| 51 | |||
| 52 | * Minimum air humidity (in a series of time frames) |
||
| 53 | |||
| 54 | * Average air humidity (in a series of time frames) |
||
| 55 | 5 | Aleksander Bešir | |
| 56 | |||
| 57 | *Light sensor* |
||
| 58 | Device reports to logic: |
||
| 59 | |||
| 60 | * Current room luminosity |
||
| 61 | |||
| 62 | Statistical analysis (user chooses the main time frame and a number of inner sections): |
||
| 63 | |||
| 64 | * Maximum room luminosity (in a series of time frames). |
||
| 65 | |||
| 66 | * Minimum room luminosity (in a series of time frames) |
||
| 67 | |||
| 68 | * Average room luminosity (in a series of time frames) |
||
| 69 | 6 | Aleksander Bešir | |
| 70 | *Computer clock* |
||
| 71 | Device reports to logic: |
||
| 72 | |||
| 73 | * Current time |
||
| 74 | |||
| 75 | Statistical analysis : none. Clock is used to trigger actions which depend on current time. |
||
| 76 | 7 | Aleksander Bešir | |
| 77 | *Smart meter*:http://en.wikipedia.org/wiki/Smart_meter |
||
| 78 | Device reports to logic: |
||
| 79 | |||
| 80 | * Current energy consumption (in kWh) |
||
| 81 | |||
| 82 | Statistical analysis (user chooses the main time frame and a number of inner sections): |
||
| 83 | |||
| 84 | * Average energy consumption (in a series of time frames) |
||
| 85 | |||
| 86 | * Sum of energy consumption (in a series of time frames) |
||
| 87 | |||
| 88 | * CO2 produced (in a series of time frames) |
||
| 89 | |||
| 90 | * Electricity costs in EUR (in a series of time frames) |
||
| 91 | |||
| 92 | h2. Controllable devices (by logic) |
||
| 93 | |||
| 94 | *Air conditioner* |
||
| 95 | Available operations: |
||
| 96 | |||
| 97 | * Increase temperature by X (paramteres: X = number of °C) |
||
| 98 | |||
| 99 | * Decrease temperature by X (paramteres: X = number of °C) |
||
| 100 | |||
| 101 | * Turn device X (paramteres: X either ON or OFF) |
||
| 102 | |||
| 103 | *Windows manager* |
||
| 104 | Available operations: |
||
| 105 | |||
| 106 | * Set windows to X (parameters: X = percentage of window openness. X = 0 closes windows. X = 100 opens windows completely.) |
||
| 107 | |||
| 108 | *Window blinds manager* |
||
| 109 | Availible operations: |
||
| 110 | |||
| 111 | * Set blinds to X (parameters: X = percentage of blinds openness) |
||
| 112 | |||
| 113 | *PC power manager* |
||
| 114 | Availible operations: |
||
| 115 | |||
| 116 | * Set number of active PC's to X (parameters: X = number of PC's that are powered on) |
||
| 117 | |||
| 118 | * Set PC X to state Y (parameters: X = PC id number. Y = either ON or OFF) |
||
| 119 | |||
| 120 | *E-mail notification sender* |
||
| 121 | Availible operations: |
||